18
GB
19
GB
Maintenance operations to be carried out every 3 months
• Remove the 2 screws from the grille with a no. 2 hexagonal spanner (provided int the accessories bag).
• Remove the grille, take out the filter and place under running water.
• Leave to dry and refit the assembly.
Maintenance operations to be carried out approximately once a
year
• Unplug and unload the appliance.
• Clean the water drain at the bottom of the wine cabinet. Pay attention that nothing is blocking this drain.
• Clean the inside of the compartments with water and a gentle cleaning product.
• Rinse thoroughly. Dry it with a soft rag.
• Replace the active carbon filter housed in the upper ventilation hole in your cabinet (see chapter 6, § VI).
Manually remove the carbon filter. It is available from your usual dealer. It must be replaced using a
manufacturer guaranteed part.
• Check that the door seals are in good condition. It is often necessary to clean the door seal. Using
unsuitable cleaning products can cause premature ageing of the seals. Certain rules must therefore be followed: whenever you clean the seal, always rinse off
any cleaning product with clear water. All traces of cleaning product must be removed from the seal. EuroCave only recommends using a mild soapy solution.
If this proves insufficient, it is possible to occasionally use an ethanol-based solution, provided that the concentration used is less than 10% and that the seal
is then rinsed thoroughly with clear water.
Possible incidents Causes Corrective action
The icon displays
The temperature
has not dropped
below the limit of
±4°C / 39°F
Check the door is closed properly.
Check the condition of the door hinge.
If you have placed a large number of bottles in your cabinet in the past few hours,
wait a short while then check the temperature again..
If the alarm persists, contact your EuroCave dealer.
The icon
is still displayed even
though I have performed the corrective
action above
Operating faults Disconnect the cabinet and contact your EuroCave dealer.
The icon
displays
Open door alarm Ensure the door is closed properly.
The icon
flashes
The relative
humidity rate
falls below 65 %
for more than 72
hours
• Add a glass of water on the humidity cassette (see chapter 6, § IV).
• In order to obtain the time interval for adding water, count the number of days
between the 1st day when water was added and the day when the pictogram was
displayed.
After a few hours the icon will go out.
The apparatus cannot lower the humidity
to the desired level.
• Empty the cabinet, remove the humidity cassette and clean the tank.
• Adjust the level of humidity to 75 % but do not install the pozzolana cassettes
or replace them with new ones.
Call the EuroCave dealer if the problem persists despite these different actions.
The icon
displays
Carbon filter
alarm
Replace the carbon filter (see chapter 6, § VI).
The icon
displays
Temperature
sensor defect
alarm
Contact your EuroCave dealer.
The wine cabinet does not switch on.
/
Contact your dealer/EuroCave after-sales service.
If your appliance appears to be functioning abnormally, contact your EuroCave dealer.
Monitoring your wine cabinet’s performance and
informing your stockist if a fault occurs are the best
way of ensuring that your appliance provides you
with years of faithful service.
Your EuroCave wine cabinet is an appliance with tried and tested performance.
Your appliance is equipped with a frost prevention
device to protect you in the event of a cold circuit
failure.
2
1
7/ EVERYDAY MAINTENANCE
8/ OPERATING FAULTS
9/ TECHNICAL FEATURES AND ENERGY DATA
Compact 59
Height Width Depth Weight when Recommended temperature range
mm mm mm empty kg T° mini °C / °F T° max °C / °F
1 temperature
V059 830 595 570 42 0 / 32 30 / 86
V259 1790 595 585 65 0 / 32 30 / 86
Multi temperature
S059 830 595 570 40 12 / 54 30 / 86
S259 1790 595 585 63 12 / 54 30 / 86
Setting accuracy: +/-1°C/ 2°F, Display accuracy: +/- 1 °C/ 2 °F.
According to delegated regulation (EU) 2019/2016 of the European Commission, access energy data about our appliances on the EPREL database by scanning
the QR code visible on your appliance's energy label.
Data relating to American energy consumption regulations
1
Comply with DEPARTMENT OF ENERGY - 10 CFR Part 430 - Energy Conservation Program: Energy Conservation Standards for Miscellaneous Refrigeration Products.
Standards
Your product complies with the following standards:
1 SAFETY DIRECTIVE 2006/95/EC
Standards EN60335-1 : 2012+ A11 : 2014
EN60335-2-24 : 2010
2 EMC 2004/108/EC
Standard EN55014-1/2
Standard 62233 :2008
3 ENVIRONMENT
Directive 2010/30/EU
Regulation 1060/2010
According to the country, EuroCave wine
cabinets contain a flammable refrigerant
gas (R600a: ISO BUTANE)
Minimum duration of guarantee offered by the manufacturer: 2 years parts.
RefeRence Model Type of door
United States
1
115V 60Hz - R600a gas
Annual energy consumption
kWh/yr
V-059V3
Single temperature Solid Technical Door 172
V-059V3 Single temperature Glass and Full Glass door 172
V-259V3 Single temperature Solid Technical Door 212
V-259V3 Single temperature Glass and Full Glass door 212
S-059V3 Multi temperature Solid Technical Door 172
S-059V3 Multi temperature Glass and Full Glass door 172
S-259V3 Multi temperature Solid Technical Door 212
S-259V3 Multi temperature Glass and Full Glass door 212