1. Remove the plug at the boom of the indoor unit.
2. Connect the supplied drain hose to the boom of the indoor unit, see Figure 20.
3. Turn the device back on. The device can be used in this way temporarily even with a
defecve pump.
Tesng your Caravan air condioner
1. Switch on your Caravan air condioner.
2. Set Cool seng : <22 °C, the display will show 6 cool indicators.
3. Let the air condioner cool for 15 minutes.
4. HOLD the Cool buon and the display shows the temperature from the outgoing cold-
temperature.
5. Release the Cool buon, display shows 5 seconds the temperature from the incoming air.
6. Aer 5 seconds the display returns to normal funcon.
If the dierence between incoming- and outgoing air is at least 10 °C the air condioner
funcon is correct.
Compressor protecon funcon
The compressor protecon funcon gives the compressor a 5-minute delay to protect the
device.
Aer operaon
CAUTION
Do not use the power cable to unplug or carry the device. Do not wind the
power cable too ghtly or in sharp corners. Do not wrap the power cable around
the device.
1. Make sure the device is switched o and the plug is removed from the power outlet.
2. Let the device cool down before touching it.
3. Wind the power cable.
4. Drain the water from the indoor-unit (Figure 20).
Maintenance
WARNING
Do not perform any repairs or modicaons to this device.
Maintenance and repairs must be carried out by a EUROM authorized professional. If the
electric cable and/or electric plug is damaged, it should be replaced by the manufacturer or its
service employee or persons with similar qualicaons to prevent risks.
31