1. Remove the plug at the boom of the indoor unit.
2. Connect the supplied drain hose to the boom of the indoor unit, see Figure 20.
3. Turn the device back on. The device can be used in this way temporarily even with a
defecve pump.
Tesng your Caravan air condioner
1. Switch on your Caravan air condioner.
2. Set Cool seng : <22 °C, the display will show 6 cool indicators.
3. Let the air condioner cool for 15 minutes.
4. HOLD the Cool buon and the display shows the temperature from the outgoing cold-
temperature.
5. Release the Cool buon, display shows 5 seconds the temperature from the incoming air.
6. Aer 5 seconds the display returns to normal funcon.
If the dierence between incoming- and outgoing air is at least 10 °C the air condioner
funcon is correct.
Compressor protecon funcon
The compressor protecon funcon gives the compressor a 5-minute delay to protect the
device.
Aer operaon
CAUTION
Do not use the power cable to unplug or carry the device. Do not wind the
power cable too ghtly or in sharp corners. Do not wrap the power cable around
the device.
1. Make sure the device is switched o and the plug is removed from the power outlet.
2. Let the device cool down before touching it.
3. Wind the power cable.
4. Drain the water from the indoor-unit (Figure 20).
Maintenance
WARNING
Do not perform any repairs or modicaons to this device.
Maintenance and repairs must be carried out by a EUROM authorized professional. If the
electric cable and/or electric plug is damaged, it should be replaced by the manufacturer or its
service employee or persons with similar qualicaons to prevent risks.