“ ” long press for 3 seconds (Advanced setting Mode)
Item
Parameters
Display
Code
Default
Unit
Data
Range
Unit - -
Description
Switch the
display working
pressure unit
a.Select to switch the Unit of working
pressure, press the right button to change
the pressure unit (Cycle : kg/cm² → Psi
→ bar→ kg/cm²), then press the SET
button once and go to next parameter
setting.
b.Stay on this screen for 30 seconds, the
display screen will back to the actual
pressure conditions automatically and the
preset data value is not stored.
c.Choose not to modify the working pressure
unit, press the SET button once, and go
to next parameter setting.
1
P-Dry sec 1~120
0.01~
10.00
P-Dry
Detection time
setting of water
shortage
Pressure of
water shortage
setting
(Dry running)
a.Select to modify the detection time after
reaching the pressure setting of water
shortage (Dry running),press the left or
right button to adjust the value, after
b.Stay on this screen for 30 seconds, the
display screen will back to the actual
pressure conditions automatically and the
preset data value is not stored.
c.Choose not to modify P-Dry detection time
setting, press the SET button once, and
go to next parameter setting.
a. Select to modify the Pressure of water
shortage, press the left or right button to
adjust the value, after finishing the setting,
press the SET button and go to next
b.Stay on this screen for 30 seconds, the
display screen will back to the actual
pressure conditions automatically and the
preset data value is not stored.
c.Choose not to modify the pressure of water
shortage, press the SET button, and go
to next parameter setting.
2
3
1~600sec
hour
Auto
Reset
Auto
Time setting of
automatic
re-start running
after warning
shutdown (Dry
running or
Over pressure)
(α value)
Auto shutdown
setting after
continuous
running
a.Select to modify automatic re-start time,
press the left or right button to adjust the
value, after finish the setting,press the SET
button, and go to next parameter setting.
The time of automatic re-start = (automatic
time setting) * (trip times)³
(Cumulative trip times is up to 10 times, if
press the right button to re-start, then the
trip times can be re-calculated.)
b.Stay on this screen for 30 seconds, the
display screen will back to the actual
pressure conditions automatically and the
preset data value is not stored.
c.Choose not to modify the automatic re-start
time, press the SET button, and go to next
parameter setting.
a.Select to modify the auto shutdown setting
after continuous running, press the left or
right button to adjust the value, after finish-
ing the setting, press the SET button and
go to next parameter setting.
St-0: Pressure controller keeps running
and won’t shut down automatically.
St-.5: Pressure controller will auto shut
down after continuously running 0.5 hours
and won’t auto restart after the shutdown.
St-1~5: Pressure controller will auto shut
down after continuously running 1~5 hours
and won’t auto restart after the shutdown.
4
5
finishing
the setting, press the SET button
kg/cm²
parameter setting.
Item
Parameters
Display
Code
Default
Unit
Data
Range
Description
and go to next parameter setting.
St-0
St-.5
St-1
~
St-5
b.Stay on this screen for 30 seconds, the
display screen will back to the actual
pressure conditions automatically and the
preset data value is not stored.
c.Choose not to modify the automatic re-start
time, press the SET button, and go to next
parameter setting.
08