2.2 Alarm in and Alarm reset
There are 4 alarm sensors in for 4 channels and 1 alarm reset in, all these
5 alarm inputs can be set to Normally Open or Normally Closed by user and
the setting menu.
SENSOR 1
SENSOR 2
SENSOR 3
SENSOR 4
8
2 1
15
9
EverPlex 4CQ
ALARM RESET
ALARM
CIRCUIT
2.2.1 ALARM IN
There are four alarm inputs for each camera.
When any alarm signal happens, the machine will do the following:
1. Switch to the full screen display of this channel.
2. Blink the channel ID with alarm message.
3. Turn on the buzzer if the buzzer setting is on.
When many alarms come up in the alarming status, the monitor screen will switch to
quad display to show all the channels which have alarm in.