29
SEASONING
Section 7 DIAGNOSTICS
The following problems may occur as indicated in the table below
FAULT POSSIBLE CAUSE ACTION RIMEDIO
Appliance does not switch on switch set to - O - set switch to - I -
power failure check plug, socket, fuses, electrical line
other contact service department
Refrigeration unit does not start set temperature has been reached set new temperature
defrosting cycle in progress wait for cycle end, switch off and then on again
control panel fault contact service department
other contact service department
Refrigeration unit runs con stantly room temperature too high provide better ventilation of room
but does not reach condenser dirty clean condenser
set temperature refrigerant needs recharging contact service department
condenser fan not running contact service department
door seals are not efcient check seals / make sure refrigerator contents
are not obstructing doors
evaporator is coated with ice defrost manually
defrost valve is open contact service department
Refrigeration unit does not control panel fault contact service department
cut out at set temperature temperature sensor defective contact service department
Build up of ice on evaporator improper use see headings 3.4
control panel fault contact service department
defrost sensor defective contact service department
Water or ice deposits drain outlet is clogged clean drain and drain outlet
in the drip tray appliance not level see heading 3.2