Everlasting 701 - Defrost and Door Event Logging

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
53
SERVICE 02 DEFROST
It records duration of the last defrost operations.
Press ENTER to visuzlize the last 16 defrost operations.
D09 22Min M=03
S 11:44 10/12/03
Each recorded defrost display the following data:
starting time and day, duration (min.) and a preogres-
sive number of occurrence from D01 to D16.
The letter M refers to how the defrost has been started:
M = 1 starting from the keyboard
M = 3 starting by interval time of fridge operation
M = 4 starting by interval time of compressor operation
M = 5 starting by time
M = 6 starting by automatic defrost
M = 7 starting by evaporator low temperature
M = 8 starting by time protection
M = 9 starting by alarm
All the others saved defrost can be selected with the UP and DOWN buttons.
If there is not any other saved defrost, the display shows the lebel:
NO DATA
Get back to Service Menu pressing MENU
.
SERVICE 03 OPEN DOOR
It records the door openings and their duration.
Press ENTER to visualize the door openings of the last day. Door openings can be re-
corded up to 31 days.
For each day of operation is dedicated a memory cell in which are recorded following data:
number of door openings, number of door opening with a duration higher than C03 parameter,
total time of door opening.
The memory can save up to 31 days in rotation.
The C01 parameter, if it is not zero, enable the microdoor slot.
05/11 01h34m
long:01 tot:03
05/11
Record day and month
01h34m Total duration of door opening
long:01 number of door opening with a duration higher
than C03 parameter
tot:03 Number of door openings