EXE Bandwidth Limiting Script
Date Revised: Jan-12-16 Revision 1.0
Link down On NCS1
- "exe-NCS-1:eth7" connected to "exe-FC-01:fm0-02-F01-P02(fm0-02)" (Link between
Ctr2(fm0-02-F01-P02(fm0-02)) port on FC01 and 10GE-SFP1(eth7) on NCS1 is down)
- "exe-NCS-1:eth6" connected to "exe-FC-02:fm0-02-F02-P02(fm0-02)" (Link between
Ctr2(fm0-02-F02-P02(fm0-02)) port on FC02 and 10GE-SFP2(eth6) on NCS1 is down)
- "exe-NCS-1:eth2" connected to "exe-FC-01:eth1" (Link between FC Cfg2 (eth1) port on
FC01 and FC CfgA (eth2) on NCS1 is down)
- "exe-NCS-1:eth3" connected to "exe-FC-02:eth1" (Link between FC Cfg2 (eth1) port on
FC02 and FC CfgB (eth3) on NCS1 is down)
Cable is swapped
- "exe-NCS-0:eth2" connected to "exe-FC-01:eth0" + "exe-NCS-0:eth2" connected to "exe-
FC-01:eth1"
1GE link is swapped on FC01. Currently, FC Cfg2 (eth1) on FC01 is connected to FC
CfgA (eth2) on NCS0 instead of connected to FC CfgA (eth2) on NCS1
- "exe-NCS-0:eth7" connected to "exe-FC-01:fm0-01-F01-P01(fm0-01)" + "exe-NCS-
0:eth7" connected to "exe-FC-01:fm0-02-F01-P02(fm0-02)"
10GE link is swapped on FC01. Currently, Ctr2 (fm0-02-F01-P02(fm0-02)) port on
FC01 is connected to 10GE-SFP1(eth7) on NCS0 instead of connected to 10GE-
SFP1(eth7) on NCS1
Peering link is disconnected
- "exe-NCS-0:eth4" connected to "exe-NCS-1:eth4"
The first Peer link between NCS0 and NCS1 is disconnected
- "exe-NCS-0:eth5" connected to "exe-NCS-1:eth5"
The second Peer link between NCS0 and NCS1 is disconnected
c. Check LED lights from the back of NCS for 1GE links and 10GE links. Reseat the SFP from
the FC’s side if any of them are not lit up. The link should be recovered after reseating.
NOTE: The LED lights for the 10GE links are located between 10GE SFPs. The top 2 LED lights
are associated with the 10GE SFP2 port. The bottom 2 LED lights are associated with the
10GE SFP1 port.
2. Port down
There are some reasons that may cause the EXE port to remain Down.
a. The Port is set to Down on the Guest Webpage:
i. Go to the Port tab on the Guest webpage, make sure Operation is set to Up.
b. The Port is set to the wrong speed:
i. Go to the Port tab on the Guest webpage, make sure Speed is set to the proper
speed (1GE/10GE).