EXE Bandwidth Limiting Script
Date Revised: Jan-12-16 Revision 1.0
EXE Connections and Configurations
The following steps should be observed when setting up the EXE.
Power Supply Connection:
The power supply comes with an external power switch mounted on a 1RU panel.
There is one switch for the power supplies at the top of the frame and one switch for the supplies at the
bottom of the frame. When the switch is in the Off position all the power modules will be shutdown,
and when the switch is returned to the On position it will cause the power modules to power back up.
Each switch has a mating cable, with four alarm connectors. The alarm connectors are required for the
power tray to current share and therefore must be plugged into the back of each operating power supply
tray.
First, connect an Ethernet cable from the Control Network to the front of the PSU unit. Use a web
browser to open the Power Supply Unit (PSU) web interface, login with username Admin and password
exeadmin. By default each PSU’s IP is set to 192.168.0.230.