Open Voltage: about 0.25V
Overload Protection: 250V DC/AC RMS
5-6. Diode and Continuity
Overload Protection: 250V DC/AC RMS
For continuity test: When the resistance is between 30Ω
and 100Ω, the buzzer may sound or may not sound. When
the resistance is more than 100Ω, the buzzer won’t sound.
5-7.1 Frequency (Auto Ranging)
5-7.2 Frequency ( through clamp )
5-8. Capacitance (Auto Ranging)
600KΩ
6KMΩ
100Ω
1KΩ
±(1.5% of rgd + 5dgts)
60MΩ 10KΩ
The approximate forward
voltage drop will be displayed
Open circuit
voltage:
about 1.5V
The built-in buzzer will sound
if the resistance is less than
about 30Ω.
Open circuit
voltage:
about 0.5V
Range RemarkIntroduction
Accuracy
±(1.0% of rdg + 5dgts)
Range
0 ~ 60MHz
Accuracy
±(1.5% of rdg + 5dgts)
Range
AccuracyRange
50 ~ 1KHz
-10-
±(8.0% of rdg + 5dgts)
60nF/600nF/6uF
60uF/400uF/20mF10sec