14.AC
15.Low Battery and replaced immediately
5. SPECIFICATIONS
Accuracy is guarantied for 1 year 23°C±5°C less than
80%RH
5-1. DC Voltage (Auto ranging)
Input Impedance: 10MΩ
Overload Protection:
600V AC RMS CAT III, 1000V AC RMS CAT II
Max. Input voltage:
600V AC RMS CAT III, 1000V AC RMS CAT II
5-2. AC Current (Auto ranging)
Measuring voltage drop: 200mV
show True-RMS value
-8-
Range Accuracy
600mV
Resolution
0.1mV ±(0.8% of rgd + 5dgts)
6V
60V
1mV
10mV
±(0.8% of rgd + 3dgts)
600V 100mV
Range Resolution Accuracy
60A
600A
10mA
100mA
±(2.5% of rgd + 10dgts)
1000A 1A
1000V 1V
±(1.0% of rgd + 5dgts)