5-3. AC Voltage (Auto ranging)
Input Impedance: 10MΩ
Input Impedance: 10MΩ
Overload Protection: 600V AC RMS CAT III, 1000V AC RMS
CAT II
Max. Input voltage: 600V AC RMS CAT III, 1000V AC RMS
CAT II
show True-RMS value
5-4. Temperature
Overload Protection: 250V DC/AC rms
5-5. Resistance (Auto Ranging)
Range Accuracy
600mV
Resolution
0.1mV ±(1.2% of rgd + 8dgts)
6V
60V
1mV
10mV
±(1.2% of rgd + 6dgts)
600V 100mV
750V 1V
±(1.2% of rgd + 8dgts)
Range AccuracyResolution
-40 ~
1370°C
-40 ~
2000°F
1ºC
-40°C~150°C:±(1% + 4)
150°C~1370°C:±(2% + 3)
302°F~2000°F:±(2.5% + 4)
-40°F~302°F:±(5% + 4)
1ºF
-9-
Range Resolution Accuracy
600Ω
6KΩ
0.1Ω
±(1.5% of rgd + 5dgts)
60KΩ 10Ω