56 01-2018 5035 01
air-brEak microswitcH
Only for standard version.
The Air-break microswitch never signals
lack of water after water has been dis-
pensed.
timE out for air-brEak filliNg
Only for standard version.
The air-break microswitch does not signal
that the water level has been reached in the
air-break if this occurs during the allotted
time when lling.
timE out for filliNg tHE boilEr
The boiler was not lled within the allotted
time.
coffEE uNit -microswitcH uNit fault-
When handling the brewing unit, the con-
trol microswitch was not activated within a
certain time limit.
It is possible that this fault is combined with
another coee unit positioning fault.
coffEE uNit -uNit start fault-
The microswitch indicates the permanence
at the rest point.
coffEE uNit -brEwiNg uNit fault-
The control microswitch indicates that the
coee unit is not in the infusion position.
coffEE uNit -DispENsiNg uNit fault-
During the infusion phase, the control
microswitch signals the movement of the
espresso unit.
coffEE uNit -uNit DiscHargE fault-
At the end of the infusion, the control micro-
switch signals that the coee unit does not
reach the “used pod discharge” position.
coffEE uNit -uNit iDlE fault-
The control microswitch indicates that the
brewing unit did not go back to the idle po-
sition after the discharge of the pod.
ovErHEatiNg watEr pump
The water pump has been activated fre-
quently for more than 10 minutes.
The fault prevents the intervention of the
thermal protection of the pump.
boilEr Error
The operating temperature of the boiler
is not reached after several temperature
measurements in a given time.
The appliance has been taken out of ser-
vice.
stEam boilEr Error
The operating temperature of the boiler
is not reached after several temperature
measurements in a given time.
The appliance has been taken out of ser-
vice.
boilEr lEak
Signals a possible loss of boiler pressure
during a “pressurised” cycle.
fully clEaNiNg tHE macHiNE
Signals that the appliance needs to be fully
cleaned.
The warning is displayed when the set time
limit or number of selections is reached.
wasHiNg tHE EsprEsso uNit usiNg poDs
Signals that the espresso unit needs to be
cleaned with sanitising pods.
The warning is displayed when the set time
limit or number of selections is reached.
fully wasHiNg tHE cappucciNo makEr
Signals that the milk circuit needs to be fully
washed (with detergent).
wasHiNg tHE cappucciNo makEr
Signals that the milk circuit needs to be
washed/ rinsed.
wasHiNg tHE mixErs
Signals that the mixers need to be washed.
The warning is displayed when the set time
limit or number of selections is reached.