EasyManua.ls Logo

Evolite EVO SPARK 600 - Maintenance and Service; Troubleshooting; Technical Specifications

Evolite EVO SPARK 600
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HAZEBOX 1500 Manual Ver. 1.00 Page 10
The earth has to be connected. The device must only be connected with an electric installation carried out in compliance with IEC
standards.
Maintenance & service
o Cleaning
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
o Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
The fixture does not work
o Check the connection of power and main fuse.
Not responding to DMX controller
o Check DMX connectors, cables to see if link properly.
o Check the address settings and DMX polarity.
o If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the previous
one.
o Try to use another DMX controller.
o Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to
DMX interface circuit.
o Check the fluid level in the tank
Technical Specifications
Spark height
1-6M
Working Temperature
-10-50
Power consumption
650w 2.3A
Fuse
220V/6A
Interface
3 pin dmx, power in/out
N.W
5.9kg
G.W
6.7kg
Dimension
305 x 305 x 340 mm
Max. connections
Max. 6PCS