EasyManua.ls Logo

Evopower SF1000 - Maintenance; Maintenance Schedule

Default Icon
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SF1000 / SF2200e Inverter Generator Owner’s Manual
www.evopower.co.uk
17
WARNING
Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction in which you can be seri-
ously hurt or killed. Always follow inspection and mainte-
nance recommendations and schedules in this owner's
manual.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
Only use OUTSIDE and far
away from windows, doors, a
nd
vents.
NEVER
use inside a home
or garage, EVEN IF doors
and windows are open.
Shut off engine before performing any maintenance. If
engine must be run, be sure area is well ventilated.
MAINTENANCE
Maintenance
Schedule
Periodic maintenance and adjustment are necessary to keep the generator in good operating condition. Perform service and
inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3).
WARNING
Accidental starting of generator can cause severe injury or
death. Before performing maintenance, disconnect spark
plug cap from spark plug.
NOTICE
Maintenance, replacement, or repair of the emission
control devices and systems may be performed by any
non-road engine repair establishment or individual.
NOTICE
The maintenance schedule applies to normal operating con-
ditions. If you operate generator under severe conditions,
such as sustained high-load or high-temperature, or use it in
unusually wet or dusty conditions, consult your servicing
dealer for recommendations applicable to your individual
needs and use.
MAINTENANCE TASK
FREQUENCY
*
Before
each use
First month
or 25 hours
of use
Every 3
months or
50 hours of
use
Every 4
months or
62.5 hours
of use
Every 6
months or
100 hours of
use
Every
year or
200 hours
of use
Fill fuel tank
X
Check engine oil level
X
Check air cleaner
X
Clean air cleaner
X
Change engine oil (SF1000)
X
Change engine oil (SF2200)
X
Check/clean spark plug
X
Clean spark arrestor
X
Check/adjust valve clearance
X
**
Clean fuel tank and strainer
X
**
Check fuel line
Every 2 years (replace if necessary)**
TABLE 3. Generator Maintenance Schedule
* Perform at every indicated month or operating hour interval, whichever comes first.
Clean more often when using generator in dusty areas.
SF2200 model only.
** It is recommended that this maintenance task be performed by a service dealer.