102808_CAPAC_MANUAL_MODEL_90W12D_SYSTEM.doc
CAUTION: NEVER use steel wool or any abrasive cleaner on an anode. If a
reference electrode is connected as an anode, it will be destroyed
within a few days. If it is connected as an anode for several minutes, it
will subsequently develop an inaccurate voltage. These points should
be remembered when checking a CAPAC
®
system.
The accuracy of this electrode is determined by comparing the CAPAC
®
Monitor meter
reading with a portable silver-silver chloride reference electrode meter.
NOTE: The reference electrode may be identified from the inboard side by
means of the 10 inches of white lead wire attached to the back of it.