102808_CAPAC_MANUAL_MODEL_90W12D_SYSTEM.doc
The controller must then be repaired. Do not leave anode connected to
battery.
3) Symptoms:
The meter reads zero.
Check:
a. Reference electrode for open or shorted wiring, as described in Service,
Paragraph 1 and 2.
b. CAPAC
®
meter, as described in Service, paragraph 3.
Bronze Fittings:
The Servicing procedure for bronze fittings is the same as for steel hulls except that
the CAPAC
®
Monitor meter will read 0.55 to 0.75 when the hull is protected. This
means that the checks given under Symptoms 2 for steel apply when the CAPAC
®
meter on a boat with bronze fittings reads 0.1 to 0.4.