Warning ............................................................. 2
Features ............................................................ 2
Important Safeguards ........................................ 2
Internal View ................................................... ...3
Mounting ............................................................ 4
Supply & Load Cable Connections .................... 5
Connecting Serial Control Cables...................... 6
Hardware Controls ............................................ 7
Dimmable Lamps Chart .................................... 7
Changing Scenes Using The Program Key ........8
Troubleshooting................................................. 9
Specification ..................................................... 9
Contents
Ex-Or
Haydock Lane, Haydock, Merseyside WA11 9UJ
Tel: 01942 719229 Fax: 01942 272767 Email: technicalsales.ex-or@honeywell.com
www.ex-or.com
W4386A
SMD810
Instruction Manual
MIXED DIMMER
SceneSelect II
Scene-setting and Dimming System

Questions and Answers

  • M
    Michael StantonAug 1, 2025
    Why do the circuit breakers keep tripping with my Ex-Or SceneSelect II SMD810 Dimmer?
    • E
      Emma JosephAug 1, 2025
      Circuit breakers may trip instantly due to a short circuit on the load, or after a delay if the dimmer is overloaded. To resolve this, check the load wiring for short circuits. Verify the dimmer loading with a current tester, remembering to de-rate for low power-factor loads and transformer losses. Also, ensure that the breaker terminals are tight.
  • M
    Michael BrownAug 7, 2025
    What to do if my Ex-Or SceneSelect II SMD810 Dimmer will not respond to control panel push buttons?
    • D
      Dr. Laurie WareAug 7, 2025
      If the dimmer isn't responding to the control panel, the control panel might be incorrectly wired or configured. Check the operation of the LEDs on the control panel. Push the button on the panel and study the response of the service LED.
  • B
    Barbara JohnsonAug 13, 2025
    How to fix fluorescent lights that won’t dim with my Ex-Or Dimmer?
    • E
      Elizabeth TaylorAug 14, 2025
      If fluorescent lights won’t dim, the ballast type might be incorrect, or the ballast may be incorrectly wired. Verify the ballast type, check the wiring against the ballast manufacturer’s diagram, and check the 1-10V/DSI settings.
  • M
    Margaret JohnsonAug 19, 2025
    What to do if the power supply indicator LED is lit, but there is no Service LED activity on my Ex-Or Dimmer?
    • D
      dennisseanAug 19, 2025
      If the power supply indicator LED is lit, but there is no Service LED activity, the supply voltage may be too low, there may be a short circuit on the network, or the control PCB could be faulty. Check that the supply voltage is at least 75% of the rated voltage. Check the 5V & 12V terminal voltages; the 5V supply must be present. Disconnect the network bus and restore power. If the issue persists, replace the control PCB.
  • E
    Eric ThompsonAug 25, 2025
    Why does my Ex-Or Dimmer not operate at all?
    • L
      Lauren FarleyAug 26, 2025
      If the dimmer does not operate at all, and there is no Service LED activity and the power supply indicator LED on the PCB is not lit, it could be due to an incorrect connection of the mains supply, or no power available. Check the power supply to the dimmer and verify the Line and Neutral input connections.

Summary

Important Safeguards

General Safety Precautions

Essential safety warnings for installation and operation.

Product Features

Power and Output Specifications

Details 40A supply, 10A dimmed/switched outputs, and 10A control outputs.

Cooling, Control, and Installation

Covers convection cooling, control options, and simple wall mounting.

Internal View and Connections

Component Identification

Diagram identifying internal components like circuit breakers and connectors.

Mounting and Installation

Selecting a Suitable Location

Guidelines for choosing a dry, well-ventilated location with adequate air gaps.

Device Fixing and Cable Entry

Instructions for fixing the device and routing supply, load, and control cables.

Cable Connections Guide

Supply and Load Terminal Connections

Details on connecting supply cables and load cables to terminal strips.

Ballast Control and Emergency Lighting

Guide for ballast control (1-10V, DSI, DALI) and emergency lighting connections.

Serial Control Cable Configuration

SceneSelect Bus and RJ12 Connections

Details RJ12 port for PC connection and permanent bus terminals.

Serial Cable Wiring and Color Coding

Permanent connection details, including cable types and color coding for data.

Bus Cable Daisy-Chain Method

Explains daisy-chain connection method for SceneSelect Bus devices.

Hardware Controls

Device Controls and Indicators

Explains AUX Input, Service LED, and Service Switch functions.

Lamp Type Compatibility

Details compatibility and dimming characteristics for various lamp types.

Programming Scene Presets

Using the Program Key

Step-by-step guide to setting scene presets using the program key.

Troubleshooting and Specifications

Problem Diagnosis and Solutions

Lists common symptoms, probable causes, and actions for resolving problems.

Device Specifications Summary

Details electrical, environmental, and physical specifications of the device.

Notes

Ex-Or SceneSelect II SMD810 Specifications

General IconGeneral
Channels1
Control ProtocolDALI
Power Supply / Input Voltage230V AC
Frequency50/60Hz
Dimming Range0-100%
ProtectionOverload, Short Circuit
Operating Voltage230V AC