Exalto Wiper Technologies type CT3N - 7
8. Power supply
The Exalto wiper control will operate correcttly if powered from 10V to 30V. Insert the
motor connectors before appllying power source. When powered the control will
execute a lamp test and then will go into standby mode.
9. Failures and signallings
9.1 Reset function
With any failure we recommend first that you perform a reset process to the control
system:
turn power off at distribution panel
remove the positive and negative feed to the relay box
make sure all motors are connected correctly tot the relay box
please leave for 30 seconds
reconnect positive and negative feeds to relay box
turn power on at distribution panel
the system will execute a lamp test
If problems continues check notes on section 8.1 or 8.2.
9.2 Motor fault
The flashing of a wiper button indicates that CT3N detects an error on a wiper.
This may happen if:
the parking switch is unconnected or damaged
the motor doesn’t run (internal self-resetting fuse in protection, motor unconnect-
ed or damaged)
the motor doesn’t run in FAST or in SLOW speed
the motor can’t be synchronized
the motor connectors have been inserted after supplying power.
9.3 Communication error
A shifting effect of the mode bar led indicates that control panel can’t communicate
with the relay box; this may happen if the flat cable is damaged or improperly con-
nected or if there is a problem with the CAN Bus terminations.