Description
Show the approx. forward voltage drop of the diode.
Overload Protection: 250V
de
or rms. ac.
Test
Voltage
OPERATING INSTRUCTIONS
DC
VOLTAGE MEASUREMENT
Vce=3V
1. Connect the red test lead to the " V.Q.
mA
"
jack
· and the
black lead to the
"COM
"
jack
.
2. Set rotary switch at desired DCV position, If the voltage
to
be
measured
is
not
known
beforehand
,
set
range
switch at the
highest
range position and then reduce it
until satisfactory resolution is obtained.
3.
Connect
test
leads
across
the
source
or
load being
measured.
4. Read voltage value on
the
LCD display along with the
polarity
of
the red lead connection.
OCCURRENT
MEASUREMENT
1.
Connectthe red test lead to the
"V
.Q.mA" jack and the
black
test
lead
to
" COM "
jaCk
. (For measurements
between 200mA and
lOA
, remove red lead
to
"1
OA
" jack.)
2. Set the rotary switch at' desired DCA position.
3. Open the circuit in which the current is to be measured.
and
connect
test
leads
in
series
with
the
circuit
4. Read .current value
on
LCD display along with the polarity
of
red lead connection.
AC
VOLTAGE
ME~SUREMENT
1. Connectthe
red
test lead to " V.Q.
mA
" jack and the black
test lead to the " COM " jaCk.
2. Set the rotary switch at desired ACV position.
3.
Connect
test
leads
across
the
source or load being
measured.
4. Read voltage value on the LCD display.
-6-