C-12 CRUSHER
TOGGLE PLATE REMOVAL / REPLACEMENT
To protect the crusher from the excessive loads generated by un-crushable objects, the Jawstock is fitted with overload
protection device - "Toggle Plate". When the permissible loads are exceeded, the Toggle Plate will collapse from elastic
buckling and the crusher will automatically shut down, providing a degree of protection to valuable machine components.
When this happens, then clear any blockages from the machine and fit the replacement toggle in the following way.
View on hydraulic control box.
2:- Stop the machine as described on
page 9.
solenoid valve
1:- Close jaw up as described on page
19 to give a 30 to 40 mm gap.
3:- Using appropriate equipment
support the toggle plate.
4 :- Remove toggle support arm tie bar
& bush. (Note:- only one bolt shown)
toggle
release
valve
accumulator
6:- Restart machine as described on page 8
and leave speed switch at position No.1
(DO NOT OPERATE THE JAW LOCK).
relief valve
5 :- Screw in Relief Valve cartridge to
disperse the accumulator pressure.
30 to 40 mm
gap
G1
G2
G3
G1
G2
G3
G1 - CHARGE GAUGE
G2 - CLAMP / ACCUM
GAUGE
G3 - WEDGE GAUGE
tie bar & bush