Low Frequency EMF (Magnetic) Measurements
1. Hold the meter steady, at arm’s length, and point its face toward
the electromagnetic field.
2. The meter displays the electromagnetic readings of individual
fields (XYZ) and the aggregated magnetic field. The magnetic
and electric fields are also shown on the bar graph.
3. Make several measurements at various locations.
4. The sensor orientation is represented by the arrows in the figure,
below
Note: It is common to pick up radiation from other nearby sources.
Apart from active sources, components connected to a source may
also act as radiators (cables in diathermy equipment, for example).
Note: Metallic objects, within the field, can amplify the field from a
distant source.
RF Strength
1. Hold the meter steady, at arm’s length, and point its face toward
the RF field.
2. The RF signal strength will display, with the units of measure as
set in the menu.
3. The RF strength display area will also show a histogram and a
bar graph indication.
Main Menu
1. Press MENU (center) to open the main menu (shown below).
2. Press SELECT (right) to cycle through the list.
3. Press ENTER (left) to set the selected option.
4. Press SELECT to choose the desired setting.
5. Press ENTER to confirm the setting, the meter will exit the menu
unless there are more settings required for the given parameter
(SOUND setting, for example); in which case, repeat the steps
above.
6. From main menu, shown below, press MENU to exit the menu.
#NAS100173; r. AC/94338/94343; en-US
4

Other manuals for Extech Instruments EMF450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments EMF450 and is the answer not in the manual?

Extech Instruments EMF450 Specifications

General IconGeneral
Sensor TypeLF - Magnetic Fields, LF- Electric Field Sensor, RF Strength
Range20mG /200mG /2000mG, 2µT /20µT /200µT, 50V/m to 2000V/m, 0.02µW/m² to 554.6mW/m²
Display resolution0.02/0.1/1, 1V/m, 0.02µW/m², 0.2µA/m, 0.2mV/m, 0.002µW/cm², 2dB
Frequency range50/60Hz, 50/60Hz, 50MHz to 3.5GHz
Accuracy± (15% + 100 digits), ± (7% + 50 digits), ± 2dB at 2.45GHz
Display4 digits Triple color TFT display
Sample rate6 seconds
SensorsTriple axes (XYZ) ELF and RF and Electric field sensor
BatteryThree (3) 1.5V alkaline batteries
Battery LifeApprox. 8 hours
Operating temperature and RH%5°C~40°C (41°F ~104°F); < 80%RH
Storage temperature and RH%-10°C to 60°C (14°F ~140°F); < 70%RH
Weight and Dimensions IconWeight and Dimensions
WeightApprox. 120g (4.2 oz.)
Dimensions115 x 60 x 21mm (4.5 x 2.4 x 0.08”)