User Manual
ExStik
®
EC500
pH / Conductivity / TDS / Salinity / Temperature Meter
Additional User Manual Translations available at www.extech.com

Questions and Answers

  • K
    kristen21Jul 27, 2025
    What to do if my Extech Instruments Measuring Instruments unit will not turn on?
    • T
      Thomas RothJul 28, 2025
      If your Extech Instruments Measuring Instruments unit won't turn on, it could be due to low or dead batteries. Replace the batteries. Also, check if the batteries are installed with the correct polarity; if not, replace them, ensuring correct polarity.
  • M
    Mary MoralesJul 31, 2025
    Why does my Extech Instruments Measuring Instruments show a 'BAT' message?
    • A
      Anthony OdonnellAug 1, 2025
      The 'BAT' message on your Extech Instruments Measuring Instruments indicates that the batteries are low and need to be replaced.
  • C
    Christopher MillsAug 5, 2025
    What to do if my Extech Instruments Measuring Instruments reading is frozen?
    • A
      Alejandro CrossAug 5, 2025
      If the reading on your Extech Instruments Measuring Instruments is frozen, the unit might be in “HOLD” mode. Press the MODE/HOLD key to exit this mode.
  • R
    Robert HortonAug 9, 2025
    What does 'RENEW' message mean on my Extech Instruments Measuring Instruments?
    • L
      Laura RitterAug 9, 2025
      The “RENEW” message on your Extech Instruments Measuring Instruments indicates that the pH sensor needs recalibration. Use fresh buffers to recalibrate the unit. If the pH sensor slope has fallen below acceptable limits, consider replacing the electrode.
  • P
    progersAug 13, 2025
    Why won't my Extech Instruments Measuring Instruments calibrate in pH mode?
    • N
      Nicole MoodyAug 13, 2025
      If your Extech Instruments Measuring Instruments unit won't calibrate in pH mode, possible causes include: a low pH slope (replace the electrode), a clogged or contaminated reference junction (clean the junction), a damaged or worn out sensing membrane (replace the electrode), or contaminated pH buffers (use fresh buffers).
  • A
    Angela LarsonAug 18, 2025
    Why won't my Extech Instruments Measuring Instruments calibrate in conductivity mode?
    • M
      Matthew LeeAug 18, 2025
      If your Extech Instruments Measuring Instruments unit won't calibrate in conductivity mode, the issue might be due to contaminated conductivity standards (use fresh standards), a dirty probe (clean the conductivity probe), a damaged conductivity probe (replace the electrode), or trapped air bubbles (tap or stir to release air bubbles).
  • S
    Samuel BeasleyAug 22, 2025
    What to do if my Extech Instruments Measuring Instruments unit will not respond to any key presses?
    • C
      Carol HesterAug 22, 2025
      If your Extech Instruments Measuring Instruments unit does not respond to key presses, perform a hard reboot. To do this, remove the batteries, hold the ON/OFF switch down for 5 seconds, and then replace the batteries.

Summary

Powering and Getting Started with ExStik EC500

Powering the ExStik

Explains the battery requirements and the ON/OFF function of the ExStik meter.

Getting Started

Provides initial setup and preparation steps for the ExStik EC500 meter.

Meter Description and Display

Front Panel Description

Describes the physical buttons and components on the front of the meter.

LCD Display

Explains the various indicators and segments shown on the meter's liquid crystal display.

Measurement Procedure

Sample Preparation

Details the steps required to prepare samples for conductivity, TDS, salinity, and pH measurements.

Measurement

Outlines the procedure for taking measurements using the ExStik EC500 meter.

Advanced Functions

Changing Measurement Function

Instructions on how to switch between pH, Conductivity, TDS, and Salinity measurement modes.

TDS Compensation Ratio

Explains how to adjust the TDS conversion ratio for accurate readings.

Storing Readings

Guide on how to store current readings and the storage capacity.

Meter Operations and Indicators

Recalling Stored Readings

Procedure for retrieving previously stored measurement data from the meter.

Clear Stored Memory

Instructions for clearing all stored readings from the meter's memory.

Changing Temperature Units

How to switch between Celsius (°C) and Fahrenheit (°F) for temperature display.

Data Hold Mode

Allows freezing the current reading on the display and storing it.

Auto Power Off

The meter automatically shuts off after 10 minutes of inactivity to save battery.

Low Battery Indication

Notifies the user when the batteries are low using a 'BAT' icon.

Calibration Procedures and Considerations

Calibration - pH (1, 2, or 3 points)

Step-by-step guide for calibrating the pH function of the meter.

CAL Reminder Display

Informs the user when a pH calibration is due based on usage cycles.

RENEW Display

Indicates when the pH probe performance has degraded.

Measurement and Display Considerations

Tips for accurate measurements, including handling frozen displays and temperature stabilization.

Reset Calibration Data

Procedure to clear all calibration data and reset the meter to default settings.

Conductivity Calibration and Techniques

Calibration - Conductivity

Guide for performing conductivity calibration using standardizing solutions.

Considerations and Techniques

Important tips for handling, cleaning, and measuring with the conductivity electrodes.

Specifications

Maintenance and Care

Battery Replacement

Step-by-step guide for replacing the batteries in the ExStik EC500 meter.

Electrode Replacement

Instructions on how to remove and attach the electrode to the meter.

Cleaning Recommendations

Troubleshooting

Warranty and Support Information

Two-year Warranty

Details the warranty period and terms for the Extech instrument.

Calibration and Repair Services

Information on obtaining calibration and repair services for Extech products.

Contact Customer Support

Provides contact details for customer support, calibration, and technical assistance.