MA1500 -EU-EN-V1.2-4/11
3
SAFETY NOTES
Do not exceed the maximum allowable input range of any function.
Do not apply voltage to meter when resistance function is selected.
Set the function switch OFF when the meter is not in use.
Remove the battery if meter is to be stored for longer than 60 days.
WARNINGS
Set function switch to the appropriate position before measuring.
When measuring volts do not switch to current/resistance modes.
Do not measure current on a circuit whose voltage exceeds 600V.
When changing ranges, always disconnect the test leads from the circuit under test.
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery or fuses.
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Always discharge capacitors and remove power from the device under test before performing
Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
This device is not a toy and must not reach children’s hands. It contains hazardous objects as
well as small parts that the children could swallow. In case a child swallows any of them,
please contact a physician immediately
Do not leave batteries and packing material lying around unattended; they can be dangerous
for children if they use them as toys
Expired or damaged batteries can cause cauterization on contact with the skin. Always,
therefore, use suitable hand gloves in such cases
Do not short-circuited the battery. Do not throw batteries into a fire.
Function Maximum Input
A AC, 1500A DC/AC
A DC 1500A DC/AC
V DC, V AC 1000V DC/AC
Resistance, Capacitance, Frequency, Diode Test 250V DC/AC
Type K Temperature 30V DC, 24V AC

Other manuals for Extech Instruments MA1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments MA1500 and is the answer not in the manual?

Extech Instruments MA1500 Specifications

General IconGeneral
BrandExtech Instruments
ModelMA1500
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals