CHAPTER 27
PAGE 14
EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
PAGE DATE: 1. July 1996
27-11-00 MAINTENANCE PRACTICES
27-11-01 Aileron Removal/Installation
1 Disconnect the actuator rod from the aileron center link-
age.
2 Disassemble the spade if necessary observing the quan-
tity and location of washers.
3 Loosen the hinge bolts and the ground bonding leads
and remove the bolts.
4 Install in reverse sequence of removal. Ensure that the
spade is installed with the same quantity and location
of washers (refer to Figure 12). Observe the second
Note of Chapter 27-01-00.
27-11-02 Aileron Rigging
Before beginning any adjustments inspect control rods,
levers and hinges for signs of wear or damage, check if the
control rod lengths correspond with the measurements
given in Chapter 27-00-02. If necessary replace parts and
correct lengths per Chapter 27-01-06.
1 Secure the control stick in the neutral position.
2 Check if the control rods connecting the torque tube
and the inner wing bellcranks have the correct length
(Refer to Chapter 27-00-02).
3 Adjust length if necessary per Chapter 27-01-06.
4 Check if the ailerons are in 0°-position (The trailing
edge bottom of the aileron is in alignment with the
trailing edge bottom of the wing as shown in Figure 11).

Other manuals for Extra 200