EasyManua.ls Logo

Extra 200 - Page 53

Extra 200
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
CHAPTER 05
PAGE 15
PAGE DATE: 1. July 1996
Inspector:
Mechanic:
Date:
Serial No.:
Inspections
as specified
each 50 hours
each 100 hours
O O 39 Inspect exhaust system attachment.
O 40 Inspect crankcase for cracks, leaks, and security of seam
bolts.
O O 41 Check engine mounted accessories such as pumps, tempera-
ture and pressure sensing units for leaks, secure mounting
and tight connections.
O O 42 Inspect all air inlet duct hoses (replace as required)
O O 43 Inspect engine mount for cracks and loose mountings.
O O 44 Inspect engine baffles free from cracks and fraying.
O 45 Inspect all wiring connected to the engine or accessories
O O 46 Inspect engine shock mounts for deterioration (replace as
required).
O 47 Check PRC PR-812 firewall sealant at all firewall penetrations
(bowden cables, around firewall fittings etc.). Refer to PRC
product information if replacement is necessary.)
O 48 Inspect alternator, cable connections and accessories.
O 49 Inspect condition and tension of alternator drive belt
O 50 Inspect security of alternator mounting
O 51 Inspect starter and starter drive
O 52 Lubricate starter drive
O O 53 Check brake fluid level (fill as required).
O O 54 Clean engine if necessary.
O O 55 Lubricate all controls per lubrication chart.
O
1
56 Overhaul or replace propeller governor as required.
O
2
56 Complete overhaul of engine or replace with factory rebuilt
SCHEDULED MAINTENANCE CHECKS
Maintenance Checks Schedule
1 refer to Woodward Service Bulletin No. 33580
2 refer to Lycoming Service Instruction No. 1009

Other manuals for Extra 200