EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
CHAPTER 05
PAGE 15
PAGE DATE: 1. July 1996
Inspector:
Mechanic:
Date:
Serial No.:
Inspections
as specified
each 50 hours
each 100 hours
O O 39 Inspect exhaust system attachment.
O 40 Inspect crankcase for cracks, leaks, and security of seam
bolts.
O O 41 Check engine mounted accessories such as pumps, tempera-
ture and pressure sensing units for leaks, secure mounting
and tight connections.
O O 42 Inspect all air inlet duct hoses (replace as required)
O O 43 Inspect engine mount for cracks and loose mountings.
O O 44 Inspect engine baffles free from cracks and fraying.
O 45 Inspect all wiring connected to the engine or accessories
O O 46 Inspect engine shock mounts for deterioration (replace as
required).
O 47 Check PRC PR-812 firewall sealant at all firewall penetrations
(bowden cables, around firewall fittings etc.). Refer to PRC
product information if replacement is necessary.)
O 48 Inspect alternator, cable connections and accessories.
O 49 Inspect condition and tension of alternator drive belt
O 50 Inspect security of alternator mounting
O 51 Inspect starter and starter drive
O 52 Lubricate starter drive
O O 53 Check brake fluid level (fill as required).
O O 54 Clean engine if necessary.
O O 55 Lubricate all controls per lubrication chart.
O
1
56 Overhaul or replace propeller governor as required.
O
2
56 Complete overhaul of engine or replace with factory rebuilt
SCHEDULED MAINTENANCE CHECKS
Maintenance Checks Schedule
1 refer to Woodward Service Bulletin No. 33580
2 refer to Lycoming Service Instruction No. 1009