EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
CHAPTER 05
PAGE 22
PAGE DATE: 1. July 1996
Inspector:
Mechanic:
Date:
Serial No.:
Inspections
as specified
each 100 hours
SCHEDULED MAINTENANCE CHECKS
Maintenance Checks Schedule
each 50 hours
Instruments
O 1 Check front and rear panel mounting for security and safety.
Check shock mounts for general condition.
O 2 Check operation, mounting, and wiring of switches for
condition and safety.
O 3 Check automatic circuit breaker mounting and wiring for
condition and safety.
O 4 Inspect stall warner system for condition and security of
installation, perform operational check.
O O 5 Check wing tip position/strobe lights or single strobe light
for security and operation.
O O 6 Inspect compass and compass deviation card for proper
indication and compensation.
O
1
7 Magnetic compass compensation.
O 8 Check pitot /static air pressure lines for condition and leaks,
perform operational check.
Electrical system
O O 1 Check engine bonding
O O 2 Check tank bonding (wing- and center tank)
O 3 Check system wiring free from fraying or cracks
O 4 Inspect battery and attachment
O O 5 Charge battery
1 Annual, each twelve calendar month