EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
CHAPTER 05
PAGE 34
PAGE DATE: 1. July 1996
UNSCHEDULED MAINTENANCE CHECKS
05-50-03 Engine Fire
After an engine fire, perform a check as described in the
following:
For damage evaluation consult the manufacturer, before the
aircraft is put back into service.
O 1 Check all cables and hoses, replace when necessary
O 2 Check engine according to the Lycoming Manual
O 3 Check fire wall and engine cowling for damage by high temperatures
(e.g. signs of blister on the protective paint) If necessary repaint the
fire protection paint ("WIEDOFLUGAT" Brandschutzfarbe N 56582
/ T508) .
05-50-04 Lightning Strike
In the event of a lightning strike in flight or on ground check
the following:
O 1 Check engine according to Lycoming Service Bulletin 401.
O 2 Check the skin of the strike area for burns and melting
O 3 Inspect bolts, fasteners, bearings and ground bonding leads for burns
and melting .
O 4 Check the electrical system, with running engine, for correct opera-
tion.
O 5 Check the avionic and antenna for correct operation.
O 6 Check the magnetic compass for correct readings.
Inspector:
Mechanic:
Inspections
Date:
Serial No.:
Inspector:
Mechanic:
Inspections
Date:
Serial No.: