Installation Guide 13
To install the Power Injector to an Ethernet data source and an Access Point:
1. Connect the Power Injector to an AC outlet (110VAC to 220VAC).
2. Connect an RJ-45 Ethernet cable between the Power Injector Data & Power Out
connector and the Access Point’s GE1/POE port.
3. Connect an RJ-45 Ethernet cable between the network data supply (host) and the
Power Injector Data In connector.
Ensure the cable length from the Ethernet source (host) to the Power Injector and
Access Point does not exceed 100 meters (333 ft).
The Power Injector has no On/Off power switch. The Injector receives power and is
ready for device connection and operation as soon as AC power is applied. Refer to
the Installation Guide shipped with the Power Injector for a description of the LEDs.
2.5 Wall Mount Instructions
A wall mount deployment requires hanging the AP-7522 Access Point with the provided
mounting bracket and two screws. The AP-7522 can be mounted on to any plaster, wood or
cement wall surface using the provided mounting bracket.
The hardware required to install the AP-7522 on a wall consists of:
Two wide-shoulder Phillips pan head self-tapping screws (M3.5 x 0.6 x 23 mm)
Mounting bracket
Optional customer provided installation tools include:
Phillips head screw driver, or drill and drill bit
CAUTION Ensure AC power is supplied to the Power Injector using
an AC cable with an appropriate ground connection
approved for the country of operation.
!