To configure a VLAN:
1 Select Configure > Policy > VLANS.
2 Select Add, or select an existing VLAN from the list.
3 Configure the following parameters:
Table 57: VLAN Configuration Settings
Field Description
Name Provide a unique name for the VLAN.
Mode Bridged@AC — The ExtremeCloud Appliance bridges trac for the station
through its interfaces, rather than routing the trac. For B@AC, topology the
station's "point of presence" on the wired network is the data plane port assigned
to the topology.
Bridged@AP — Assigned to APs, the AP bridges trac between its wired and
wireless interfaces without involving the ExtremeCloud Appliance. The station's
"point of presence" on the wired network for a bridged at AP topology is the AP's
wired port.
Fabric Attach — The Fabric Attach topology type allows an AP to attach to a
Shortest Path Bridging (Fabric Connect) Network. The client component on the
AP communicates directly with the server on an edge switch (or it can
communicate with the server through a proxy) to allow the AP to request VLAN to
I-SID (backbone Service Identifier [IEEE 802.1 ah] mappings). The Fabric Attach
topology type is similar to B@AP with the added I-SID parameter. Fabric Attach
can be configured on the ExtremeCloud Appliance anywhere a B@AP topology
can be configured.
VLAN ID Specify the VLAN ID.
Note: It is possible to configure a unique VLAN ID when configuring a role. This
provides more flexibility in the Contain to VLAN default Action.
The VLAN ID range is (1 - 4094). 4094 is reserved for Internal VLAN ID.
I-SID For Fabric Attach, enter a unique VLAN identifier and a unique I-SID (service
identifier)
The I-SID range is (1-15999999).
Tagged Trac If you have more than one VLAN on a port, enable tagging to identify to which
VLAN the trac belongs. Ensure that the tagged vs. untagged state is consistent
with the switch port configuration.
Fabric Attach topologies are always tagged.
Port The port for network trac bridged at controller (for example, physical ports:
Port0, Port1, Port3, Port4).
Layer 3 Check this box when configuring parameters for the network layer (B@AC).
Note: The Certificates button displays to configure browser certificates for captive
portal security.
Layer 3 Parameters
Remote Settings: IP
Address
The IP Address of a remote server on which the VLAN resides.
IP Address IP address of the VLAN. Wireless clients can access ExtremeCloud Appliance via
this IP address.
FQDN Fully-Qualified Domain Name
Configure
ExtremeCloud Appliance User Guide for version 4.36.03 138