Control Meeasure
Class 1
Class 2
Class 3a
Class 3b
Class 4
Activation Warn-
ing Systems
No requirement
No requirement
No requirement
Should have
Shall have
Indoor Laser
No requirement
No requirement
No requirement
Shall have
Shall have
XE Optics
Nominal Hazard
Nominal Hazard
Lasers Control
Zone Analysis
Zone Analysis
Required
Labels
Shall have
Shall have
Shall have
Shall have
Shall have
Area Posting
No requirement
No requirement
Should have
Shall have Nomi-
nal Hazard Zone
Analysis Required
Shall have Nomi-
nal Hazard Zone
Analysis Required
Standard Operat-
ing Procedures
No requirement
No requirement
No requirement
Should have
Shall have
Education and
Training
No Requirements
Should have
Should have
Shall have
Shall have
Authorized Per-
sonal
No Requirements
No Requirements
No Requirements
Shall have
Shall have
Warning Signs
No Requirements
Should have
Should have
Shall have
Shall have
and Labels
Nominal Hazard
Zone Analysis
Required
Nominal Hazard
Zone Analysis
Required
Page of 22 26