24
LOCK
24 VDC
- + +
+ -
24 VDC
MAG LOCK
24V AC
MAGLOCK KIT OPTION
Maglock connection
The prewired enclosure comes with dedicated terminal
blocks for the connection of a relay to drive a Maglock.
The Maglock kit can be ordered separately as an accessory.
Refer to this schematic for the connections.
If using non-FAAC relay make sure the minimum switch volt-
age is less than 12Vac
SHADOW
INPUT
Line Voltage
MOTOR
ON
24 VDC
- +
SHADOW
LOOP
120V or 230 AC
SHADOW KIT OPTION
8
7
10
1
2
5
Shadow Loop kit option
The prewired enclosure comes with dedicated terminal
blocks for the connection of a relay and a loop detec-
tor socket to implement the shadow loop functionality. The
Shadow loop kit can be ordered separately as an accessory.
Refer to this schematic for the connections.

Other manuals for FAAC 422