18
ENGLISH
Tab. 3/a
LOGIC ”A
PULSES
GATE STATUS
OPEN-A OPEN-B STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens the leaf and closes it
after pause time
/
Opens leaf for the partial
opening time and closes
after pause time
/
No effect (OPEN disabled) No effect No effect (OPEN disabled)
OPEN on PAUSE
Reloads pause time
/
Stops operation
No effect
Reloads pause time
/
(OPEN disabled)
No effect (OPEN disabled)
ON CLOSING
Re-opens the leaf immediately
/
No effect (saves OPEN) see paragraph 5.2.
Stops and, on release,
reverses on opening
Reverses on opening for 2”
0
ON OPENING
No effect
/
see paragraph 5.2. No effect
Stops and, on release,
continues opening
Reverses on closing for 2”
0
STOPPED Closes the leaf No effect (OPEN disabled) No effect No effect (OPEN disabled)
Tab. 3/b
LOGIC AP”
PULSES
GATE STATUS
OPEN-A OPEN-B STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens the leaf and closes it
after pause time
/
Opens leaf for the partial
opening time and closes
after pause time
/
No effect (OPEN disabled) No effect No effect (OPEN disabled)
OPEN on PAUSE
Re-closes the leaf immediately
Stops operation
No effect
Reloads pause time
/
(OPEN disabled)
No effect (OPEN disabled)
ON CLOSING
Re-opens the leaf immediately
/
No effect (saves OPEN) see paragraph 5.2.
Stops and, on release,
reverses on opening
Reverses on opening for 2”
0
ON OPENING Stops operation see paragraph 5.2. No effect
Stops and, on release,
continues opening
Reverses on closing for 2”
0
STOPPED Closes the leaf No effect (OPEN disabled) No effect No effect (OPEN disabled)
Tab. 3/c
LOGIC ”S”
PULSES
GATE STATUS
OPEN-A OPEN-B STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens leaves and closes
them after pause time
Opens leaf for the partial
opening time and closes
after pause time
/
No effect (OPEN disabled) No effect No effect (OPEN disabled)
OPEN on PAUSE
Re-closes the leaf immediately
Stops operation
No effect Closes after 5” (OPEN disabled) No effect (OPEN disabled)
ON CLOSING
Re-opens the leaf immediately No effect (saves OPEN) see paragraph 5.2.
Stops and, on release,
reverses on opening
Reverses on opening for 2”
0
ON OPENING Re-closes the leaf immediately see paragraph 5.2. No effect
Stops and, on release,
continues opening
Reverses on closing for 2”
0
STOPPED Closes the leaf No effect (OPEN disabled) No effect No effect (OPEN disabled)