32
ENGLISH
fig.55
INSTALLING AN ASSEMBLED AUTOMATED SYSTEM
The free-standing profile is supplied already assembled to the
support profile and with side brackets already fitted on the
cross beam fig.55
• Secure the cross beam to the wall using the holes on the
side plates (fig. 55. ) and by means of suitable dowels (not
standard-supplied).
According to the cross beam length, intermediate fastening
operations can be required and executed by means of the
guide shown in fig.54.
A central fastening is in any case recommended also for a
length below 3000mm.
If you prefer, a fastening to the wall can be performed but the
free-standing profile is not prepared for this.
To drill, follow the instructions below:
1) Remove the side brackets
2) Disassemble the support profile from the free-standing
profile.
3) Drill the necessary holes on the free-standing profile in the
position shown in fig.54 .