Inputs
Outputs
- RESET: That input allows the load limiter to power the valve ELV1 for a short period, even if the load value
exceedes the load limit. During this time, the user is able to move the machine in order to return into a safety
position. Working conditions are not monitored when reset functionality is enabled, user is responsible for possible
machine damage.
- LIMIT REDUCTION (critical working area): It is useful when a working area is more critical than other: when its
value is low, a reduced pressure threshold is used.
- INCREASE THRESHOLD (optional): that input has to be coupled with first boom descent manoeuvre. When input
value goes high, the load limit threshold is increased by a fixed value (specified in a configuration parameter), in
order to offset the pressure increase due to overcenter valves which operate during this manoeuvre.
- PRESSURE transducer input: 4÷20 mA.
- INPUT DV: It allows to connect the load limiter to a remote control in a safety way.
- DIFFERENT POWER SUPPLY for powered outputs, which includes a disconnect relay with feedback control.
Emergency button can be connected to this input.
- Powered output to drive bypass valve coil. The board implements a feedback current control on the mentioned
output.
- Two powered output to drive external optional lamps. The mentioned outputs are driven as well as the leds into
emergency button box (90% and 100%).