EasyManua.ls Logo

FABER-COM CLG-SL - Pagina 5

FABER-COM CLG-SL
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAP2 / MAP2LCLG-SL
FABER-COM srl - Via Romana 36/1 - 42028 Poviglio (RE) - Italy Tel. +39-0522-960428 Fax. +39-0522-969644 - www.fabercom.it
\Prodotti\Limitatore CLG\PCLG-LxE[CLG-SL- Barra LED]\Documenti\SM#Limitatore CLG-SL_v102 - 19/04/2017
COM
FABER -
PRG2-DEC
NEXTNEXTPREVPREV
COM
FABER -
PRG2-CLG
NEXTNEXTPREVPREV
1
2
3
3
2
1
ELV1
FU
SE-5A
1
2P+T
2x1+2x0,5
L=1.1m
2x1+2x0,5
L= 2,5 m
3x0,75
2x0.75
L=1.2m
2x0.75 L=2.0m
(protection conduit ø ext.=11 mm)
2x1
L=1.0m
2x1.5
L=1.5m
÷20 mA
4
2 fi ia
l
÷20 mA
4
2 fi ia
l
2
3
4
90%
100%
5
Power
20
40
60
80
90
100%
CLG-SL
!
1
2
3
3
2
1
EMERGENZE
con LED 90% e 100%
ALIMENTAZIONE
ELV1
F
U
S
E
CABLAGGIO
Riarmo
Incremento
Decremento
1
+ (1)
- (2)
2P+T
Connettore per
il collegamento
del programmatore
Trasduttore di pressione
a 2 fili 4÷20 mA (NON INCLUSO)
4x0,75
L=0.4m
4x0,75
L= 3 m
2x1
L=1.3m
2x1
L=1.3m
2x1 L=5.0m
(in guaina corrugata ø est.=11 mm)
2x1
L=1m
2x1.5
L=1.5m
2x0.75 L=5.2m
(in guaina corrugata øest.=11mm)
3x0.75
L=0.25m
2x1
L=0.20m
4÷20 mA
2 ia
fil
4÷20 mA
2 ia
fil
cavetto sez. 0,5 - L.: 30 cm.
per collegamento DV dal radio
(all' interno della guaina)
2
6
3
7
4
5
+ (blu)
90% (marrone)
100%(grigio)
1
2
3
4
4
3
2
1
Power
20
40
60
80
90
100%
CLG-SL
!
2x1
L=1.3m
6
7
1
2
3
3
2
1
F E
AUS -5
1
2
7
3
4
L=5m
L=0,5m
L=0,5m
4
÷
20
mA
a 2
i
l
f i
L=3m
6
COM
FABER -
PRG2-DEC
NEXTNEXTPREVPREV
COM
FABER -
PRG2-CLG
NEXTNEXTPREVPREV
COM
FABER -
PRG2-CLG
NEXTNEXTPREVPREV
2x0.75
L=1.2m
2x1
L=1.3m
+ (1)
- (2)
2x1.5
L=1.5m
ELV1
Power
20
40
60
80
90
100%
CLG-SL
!
Page 5 / 6
ELECTRONIC BOARD
CLG
POWER SUPPLY
Connector to plug
the PRG2_CLG
EMERGENCY BUTTONS
with LED 90% and 100%
wire 0,5mm - L.: 30 cm.
to connect the remote control DV
(hidden under the conduit)
Programming
keyboard
PRG2-CLG
2x0.75 L=5.0m
(protection conduit
øext.=11mm)
RESET
LIMIT REDUCTION
2
Code PASMLMxxx : Control unit CLG + cabling
Code PCLG-LyE : Only control unit
Code A1003720022 : 400bar Pressure transducer
Code A1003720021 : 250bar Pressure transducer
Code PPRG2MC:programming keyboard
Ordering code of system shown in figure :
Code PASMLM0027 : Control unit CLG + cabling
Code A1003720022 : 400bar Pressure transducer
Pressure transducer,
4÷20 mA, M12 connector
INCREASE
THRESHOLD
(optional)
2x0.75 L=5.0m
(protection conduit øext.=11mm)
Ordering code
It is possible to connect a
LED bar which signals when
load exceed the 90% or 100%