Error solving manual.
CNC 8060
CNC 8065
·48·
(REF: 1709)
1375 'M17/M29/#RET expected'
DETECTION During execution.
CAUSE M17, M29 or #RET has not been programmed at the end of the subroutine.
SOLUTION Check the program.
1376 'No default name has been defined for the C axis'
DETECTION During execution.
CAUSE In the #CAX instruction, the name of the C axis is missing and the default name
(parameter CAXIS) is not indicated in the machine parameters.
SOLUTION In the #CAX instruction, indicate the name that will identify the "C" axis.
1377 'Parameter written with wrong index'
DETECTION During execution.
CAUSE The arithmetic parameter does not exist or is write-protected.
SOLUTION Check the program. Check the valid arithmetic parameter range in the machine
parameters.
The write-protected global parameters are those defined by machine parameters
ROPARMIN - ROPARMAX.
1378 'Parameter read with wrong index'
DETECTION During execution.
CAUSE The arithmetic parameter does not exist; it is not within the range admitted by the
machine parameters.
SOLUTION Check the program. Check the valid arithmetic parameter range in the machine
parameters.
1380 'Canned cycle programmed wrong'
DETECTION During execution.
CAUSE In the block defining a canned cycle, nothing must be programmed after the cycle
parameters.
SOLUTION Check the program.
1381 'Nonexistent canned cycle'
DETECTION During execution.
CAUSE The programmed canned cycle does not exist.
SOLUTION Check the program.
1382 'Parameter not allowed in canned cycle'
DETECTION During execution.
CAUSE One of the programmed parameters is not allowed for that canned cycle.
SOLUTION Check the programming manual for the parameters required and allowed by each
canned cycle.
1383 'Mandatory parameter not programmed in canned cycle'
DETECTION During execution.
CAUSE A parameter required in the canned cycle has not been programmed.
SOLUTION Check the programming manual for the parameters required and allowed by each
canned cycle.
Machine parameters. Valid range.
MINLOCP - MAXLOCP Local arithmetic parameters.
MINGLBP - MAXGLBP Global arithmetic parameters.
MINCOMP - MAXCOMP Common arithmetic parameters.
Machine parameters. Valid range.
MINLOCP - MAXLOCP Local arithmetic parameters.
MINGLBP - MAXGLBP Global arithmetic parameters.
MINCOMP - MAXCOMP Common arithmetic parameters.

Related product manuals