ENGLISH MANUAL FOR USE AND MAINTENANCE ADVANCE PLUS
33
HACCP
When the oven is operating with the “Core
probe” or “Delta” function, the data with which it
is operating must be stored in order to comply
with current legislation with respect to HACCP.
The oven saves all the data for the operating
mode, Humidity, TC and TN (the lowest value
between TN1 and TN5) every minute while you
remain in the function in question. The data
must be stored for one month.
These data can be displayed on the screen or
downloaded to an external device using a de
USB or Ethernet.
Usage:
1. Connect the PC to the oven when it is
switched off.
2. Switch on the oven.
3. Confirm the option “START HACCP”.
4. After the message “END HACCP
DOWNLOAD” switch off the oven.
DESCALING
This function is used to access the descaling
cycle.
1) Press the descaling button.
2) Select time.
3) Warning “SPRAY DESCALER” (3 minutes).
4) Insert descaler in steam generator (rear
section of the oven).
5) Confirm.
6) On completion the following message is
displayed
“END DESCALING”
To descale, apply the chemical product in
the quantities indicated by the
manufacturer.
The volume of each generator is:
AE-APE
AG-APG
061
3,25 litre
7,3 litre
101
5.5 litre
7,3 litre
201
7 litre
12,3 litre
102
7 litre
12,3 litre
202
11,7 litre
15,3 litre
We recommend using a phosphoric acid
based product with a concentration of 30-
40%.
In this concentration, we recommend using
25% of the generator volume. In all cases,
please observe manufacturer’s
recommendations.