If the motor does not start within 10 seconds of a start request.
If a speed of 500 rpm is not exceeded within 20 seconds of a start
request.
CONSEQUENCE
The oven is completely disabled
E8: Needs water
DESCRIPTION
The VDV is observed to have been running for 7 or more minutes and the
maximum level has not been reached.
CONSEQUENCE
It is only possible to operate in Convection mode
E9: Err. Drainage
DESCRIPTION
The VAC is observed to have been running for 1 or more minutes and the
minimum level has not been reached.
CONSEQUENCE
It is only possible to operate in Convection mode
E10: CV Fault
DESCRIPTION
If TG<93ºC, when CV is active, in 3 minutes, TG does not rise 3 or more
degrees.
CONSEQUENCE
It is only possible to operate in Convection mode
E11: CC Fault
DESCRIPTION
The CC operates and in 12 minutes, the TC does not rise 3 or more
degrees.
CONSEQUENCE
The oven is completely disabled
E12: Temp. High
DESCRIPTION
The controller NTC reaches 60ºC, but does not exceed 70ºC
CONSEQUENCE
The oven operates normally and the bell is not heard. This message is
displayed for 3 seconds every 30 seconds.
E13: VCC fault (Only GAS ovens)
DESCRIPTION
VCC does not respond to the gas control and is at maximum speed.
CONSEQUENCE
The oven is completely disabled
E14: VCC fault (Only GAS ovens)
Description:
VCC does not respond to gas control and has stopped.
CONSEQUENCE
The oven is completely disabled
E15: VCC fault (Only GAS ovens)
DESCRIPTION
VCC does not respond to the gas control and the speed is not stable.
CONSEQUENCE
The oven is completely disabled
E16: VCV fault (Only GAS ovens)
DESCRIPTION
VCV does not respond to the gas control and is at maximum speed.
CONSEQUENCE
It is only possible to operate in Convection mode
E17: VCV fault (Only GAS ovens)
DESCRIPTION
VCV does not respond to gas control and has stopped.