CONSEQUENCE
It is only possible to operate in Convection mode
E18: VCV fault (Only GAS ovens)
DESCRIPTION
VCV does not respond to the gas control and the speed is not stable.
CONSEQUENCE
It is only possible to operate in Convection mode
E19: VCC2 fault (Only GAS ovens)
DESCRIPTION
VCC2 does not respond to the gas control and is at maximum speed.
CONSEQUENCE
The oven is completely disabled.
E20: VCC2 fault (Only GAS ovens)
DESCRIPTION
VCC2 does not respond to gas control and has stopped.
CONSEQUENCE
The oven is completely disabled.
E21: VCC2 fault (Only GAS ovens)
DESCRIPTION
VCC2 does not respond to the gas control and the speed is not stable.
CONSEQUENCE
The oven is completely disabled.
E22: Temp. High
DESCRIPTION
The controller NTC exceeds 70ºC
CONSEQUENCE
The oven is completely disabled.
E23: Err. Chimney
DESCRIPTION
Fluepipe motor faulty
CONSEQUENCE
The oven is completely disabled.
E24: Out of Service
DESCRIPTION
Communication error. The chamber card does not respond.
CONSEQUENCE
The oven is completely disabled.
E25: Out of Service
DESCRIPTION
Communication error. The control holder card does not respond.
CONSEQUENCE
The oven is completely disabled.
E26: Vapour Connection
DESCRIPTION
Communication error. The boiler card does not respond.
CONSEQUENCE
It is only possible to operate in Convection mode
E27: BMF GAS1 (Only GAS ovens)
DESCRIPTION
Communication error. The gas card does not respond.
CONSEQUENCE
The oven is completely disabled.
E28: BMF GAS2 (Only GAS ovens)
DESCRIPTION
Communication error. The second gas card does not respond.
CONSEQUENCE
The oven is completely disabled.