SERVICE MANUAL
EVO FRONT LOADING DISHWASHER
If the water pressure is lower than
the recommended, a pressure pump
must be installed. Please contact
your supplier or the manufacturer to
request the PRESSURE PUMP KIT.
The water inlet temperature is also important. Hot water should be used to optimise the machine operation, as the
use of cold water will increase the times required to reach the operating temperatures and productivity will be
reduced. If using hot water, the water temperature must not exceed 60 ⁰C / 140 ºF.
For the correct hydraulic installation of the machine, you must:
• Connect the appliance to a water supply which complies with the requirements specified above. All the
machines have a ¾” screw-on water hose connection. Old or used hoses must NOT be used.
• Install a shut-off valve on the water supply close to the machine in an accessible position.
• Check that the mains pressure is within the range indicated above.
• Check that there are no leaks
Connect the machine to the mains water supply at the points indicated,
using the hose supplied.
The pressure of the incoming water should be between 200 and 400 kPa
(2÷4 kg/cm
2
= 2÷4 bar). Fagor Industrial recommends 250 kPa.
PLUS AND
ADVANCE
Max. 400 kPa 4 bar 4.1 kg/cm
2
58 psi
Min. Max.
Cold Water 15 ºC / 59 ºF
Hot Water
H
Only AU: Supplies hose and
counterflow prevention device
assembly