Power supplies
2.
94
Ref.1912
DDS
HARDWARE
· 86 ·
FAGOR supplies the right CHOKE RPS for this application. See the relevant
cable section in table T. H2/23. Note that the cable must be shielded.
The data for the RPS choke connection terminals is:
WARNING. Chokes are a must for the operation of a regenerative power
supply. Installing a choke with an inductance other than the one
recommended for a choke may cause severe damage to the unit.
T. H2/31 RPS CHOKE connection terminals. Technical data.
CHOKES RPS-75-3 RPS-45 RPS-20
Gap (mm) - - 10.16
Min./max. tightening torque (N·m) 1520 6 1.5
Section (mm²) 70 35 10