7.2 MOD. “C”: Fault diagnosis y warnings on display
The errors are shown on the DISPLAY (Fig. 9) with a flashing error warning and a buzzer alarm. The buzzer
alarm has a cycle of 30 s active and 150 s off until it is switched off after 15 minutes. The warning message
continues to be displayed until the error is resolved or the machine is switched off.
Faulty boiler temperature probe.
Faulty tank temperature probe.
Tank overheating
TT > 90 ºC
Boiler overheating
TC > 105 ºC
Boiler heating faulty.
TC does not increase 3 ºC in 5 minutes.
Tank heating failure.
60 min without reaching temperature.
The boiler does not fill.
After 10 minutes, the boiler does not fill.
The tank does not fill.
After 30 minutes, the tank does not fill.
Does not drain.
After 1 minute with the drainage pump running,
the level of the tank has not dropped 5 mm.
Rinse error.
The boiler level does not decrease during the
rinse cycle.
Max. tank level error.
The tank contains too much water.
The drainage pump runs
until the water level is
lowered.
E12- TANK MIN.
LEVEL TANK
Min. tank level error
The tank is running dry while in standby mode.