B-82604EN/01 SAFETY 1.SAFETY PRECAUTIONS
-
s-9 -
(4) The teach pendant operator should pay careful attention so that
no other workers enter the robot work area.
NOTE
In addition to the above, the teach pendant enable
switch and the deadman's switch also have the
following function.By pressing the deadman's switch
while the enable switch is on, the emergency stop
factor (normally the safety gate) connected to the
controller is invalidated. In this case, it is possible
for an operator to enter the fence during teach
operation without pressing the EMERGENCY STOP
button. In other words, the system understands
that the combined operations of pressing the teach
pendant enable switch and pressing the deadman's
switch indicates the start of teaching.
The teach pendant operator should be well aware
that the safety gate is not functional under this
condition and bear full responsibility to ensure that
no one enters the fence during teaching.