1.SAFETY PRECAUTIONS SAFETY B-82604EN/01
-s-14-
1.4 SAFETY OF THE END EFFECTOR
1.4.1 Precautions in Programming
(1) To control the pneumatic, hydraulic and electric actuators,
carefully consider the necessary time delay after issuing each
control command up to actual motion and ensure safe control.
(3) Provide the end effector with a limit switch, and control the
robot system by monitoring the state of the end effector.
1.5 SAFETY IN MAINTENANCE
(1) Never enter the robot work area while the robot is operating.
Turn off the power before entering the robot work area for
inspection and maintenance.
(2) If it is necessary to enter the robot work area with the power
turned on, first press the EMERGENCY STOP button on the
operator's box.
(3) When replacing or reinstalling components, take care to prevent
foreign matter from entering the system. When replacing the
parts in the pneumatic system, be sure to reduce the pressure in
the piping to zero by turning the pressure control on the air
regulator.
(4) When handling each unit or printed circuit board in the
controller during inspection, turn off the power of the controller
and turn off the circuit breaker to protect against electric shock.
(5) When replacing parts, be sure to use those specified by FANUC.
In particular, never use fuses or other parts of non-specified
ratings. They may cause a fire or result in damage to the
components in the controller.
(6) Before restarting the robot, be sure to check that no one is in the
robot work area and that the robot and its peripheral devices are
all in the normal operating state.