6.3. ROTOR BEARINGS LUBRICATION
Lubricant: AGIP GREASE MU EP 2 lithium-type grease (or equivalent)
Frequency: each 20 working hours
To perform lubrication (see pictures):
turn the cover (1) and inject grease through the nipple (2);
inject grease through the nipple (3).
IMPORTANT
Make sure to clean the fitting zerk before using the grease gun.
Do not let excess grease collect on or around parts, particularly when operating in sandy areas.
6.4. ROLLER BEARINGS LUBRICATION
Lubricant: AGIP GREASE MU EP 2 lithium-type grease (or equivalent)
Frequency: each 20 working hours
To perform lubrication, inject grease into the nipples (1) and (2), located on the upper part of the roller
bearing supports (see pictures).