4-1
Chapter 4 Sequential Instructions
The sequential instructions of FBs-PLC shown in this chapter are also listed in section 3.1. Please refer to Chapter 1,
"PLC Ladder diagram and the Coding rules of Mnemonic instruction", for the coding rules in applying those instructions. In
this chapter, we only introduce the applicable operands, ranges and element characteristics, functionality.
4.1 Valid O
p
erand of Se
q
uential Instructions
X Y M SM S T C TR OPEN SHORT
Operand
Ranges
Instruction
X0
|
X255
Y0
|
Y255
M0
|
M1911
M1912
|
M2001
S0
|
S999
T0
|
T255
C0
|
C255
TR0
|
TR39
— —
ORG ○ ○ ○ ○ ○ ○ ○ ○ ○
ORG NOT ○ ○ ○ ○ ○ ○ ○
ORG TU ○ ○ ○ ○
※
○ ○ ○
ORG TD ○ ○ ○ ○
※
○ ○ ○
LD ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
LD NOT ○ ○ ○ ○ ○ ○ ○
LD TU ○ ○ ○ ○
※
○ ○ ○
LD TD ○ ○ ○ ○
※
○ ○ ○
AND ○ ○ ○ ○ ○ ○ ○ ○ ○
AND NOT ○ ○ ○ ○ ○ ○ ○
AND TU ○ ○ ○ ○
※
○ ○ ○
AND TD ○ ○ ○ ○
※
○ ○ ○
OR ○ ○ ○ ○ ○ ○ ○ ○ ○
OR NOT ○ ○ ○ ○ ○ ○ ○
OR TU ○ ○ ○ ○
※
○ ○ ○
OR TD ○ ○ ○ ○
※
○ ○ ○
OUT ○ ○ ○
※
○ ○
OUT NOT ○ ○ ○
※
○
OUT L ○
ANDLD
−
ORLD
−
TU
−
TD
−
NOT
−
SET ○ ○ ○
※
○