EasyManua.ls Logo

FeelElec FY8300S-20M - User Manual

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
FeelElec
FY8300S Series Fully Numerical Control
Three +Four Channel Function/Arbitrary Waveform
Generator
Users Manual
Rev1.0 May,2019

Questions and Answers

  • B
    Bradley MarshallAug 9, 2025
    What to do if my FeelElec Inverter set correctly, but no waveform output?
    • J
      John MendezAug 9, 2025
      If your FeelElec Inverter isn't outputting a waveform despite correct settings, here's what to check: * Ensure the BNC cable is securely connected to the CH1, CH2, or CH3 connector. * Inspect the BNC cable for any internal damage. * Verify the BNC cable is properly connected to your testing instrument. * Confirm that the indicator lights for CH1, CH2, or CH3 are illuminated. If not, press the corresponding button to activate them.
  • J
    James BondAug 20, 2025
    How to fix FeelElec Inverter screen if it is still dark after switch on?
    • M
      Michael PowellAug 20, 2025
      If the screen of your FeelElec Inverter remains dark after switching it on, try the following: 1. Ensure the power is correctly connected. 2. Verify that the power switch is fully engaged. 3. Restart the device.
  • M
    Molly OrtegaAug 28, 2025
    Why are CH2 and CH3 locked on my FeelElec Inverter?
    • K
      kwadeAug 29, 2025
      To unlock CH2 and CH3 on your FeelElec Inverter: 1. Verify that the signal generator is operating in synchronous state. Press the SYNC button to access the synchronization settings and cancel any synchronization parameters. 2. If the issue persists, restart the generator.

Summary

Product Introduction

Main Features

Overview of the primary capabilities and technological highlights of the FY8300S series signal generator.

Quick Start

General Inspection

Procedure for inspecting the instrument and its contents upon delivery.

Front Panel Overview

Back Panel Overview

Power On and Inspection

User Interface

Front Panel Operations

Select Waveform

Instructions for selecting desired waveform types from the available options.

Set Frequency

Adjusting the output frequency parameter for waveforms.

Set Amplitude

Setting the amplitude level for the output signal.

Set Offset

Adjusting the DC offset voltage for the output signal.

Set Phase

Configuring the phase shift of the output signal.

Example: Output Sine Waveform

A detailed walkthrough of outputting a sine waveform with specific parameters.

Modulation Function

Frequency Meter;Counter

Sweep

System Configuration and Auxiliary Functions

Troubleshooting

Technical Specification

Appendix

Appendix A: Safety Notes

Essential safety guidelines and precautions for the proper use of the instrument.

Appendix B: Warning and personal injury

Critical warnings regarding potential risks, hazards, and liability.

FeelElec FY8300S-20M Specifications

General IconGeneral
ModelFY8300S-20M
CategoryInverter
BrandFeelElec
Output Power2000W
Peak Power4000W
Input Voltage12V DC
Output Voltage220V AC
Output Frequency50Hz
Protection FeaturesOverload, Overheat, Short Circuit, Low Voltage, High Voltage
CoolingFan
Efficiency≥ 90%
No-Load Current≤ 0.8A