43
!
"
#
Edgebander with glue pot
G 200 / G 220
Reset of overload cutout switches:
• Switch off the main power supply.
• Position the main switch on 0/OFF and padlock it
• reset to ON the overload cutout switches
If it is still necessary to re-set the switches it is important
to verify that:
• the value set is correct,
• the movement connected to the motors are free to
move,
• the motors temperature is not too high (80-90° C) and
• the motors are free of brake circuit.
It is important that these controls will be done by a elec-
trical technican.
The access to the electrical box is not foreseen for other
operations, but only for special maintenance to be car-
ried out by a qualified electrician or authorized techni-
cal personnel of manufacturer.
Access the electrical box in the control system panel to
replace the fuses. Proceed as follows:
• Switch off the main power supply.
• Position the main switch on 0/OFF and padlock it.
• Disconnect the compressed air power supply tube.
• Unscrew the screws which lock the electrical panel.
• Open the box.
• Replace the burnt fuses and repeat the procedure in
reverse oder.
! Control panel
" Switch
# Fuse
Maintenance
10.3.6 Replacing fuses/ Re-setting automatic switches
Fig. 37: Changing the fuses
Fig. 38: Changing the fuses
Fig. 39: Changing the fuses