Page 15 of 17
Rudolf Dieselstraat 15A, Nijverdal, Nederland. +31 523 0613439. Mail: Info@ferlin.nl
ii. If point i. is correct, check the measured dosing time. Go to the recipe screen
and check the value for the dosing time. Does it match the dosing time on
the injection moulding machine? If not, the Ferlin One can be set to a fixed
dosing time. Go to Settings -> General -> production mode -> injection
moulding and select fixed time. Go back to the main screen and then to the
recipe. Enter the desired dosing time here.
7. Unstable dosing weight
a. This alarm appears when the Ferlin One has not been able to perform a stable
weighing for 2 consecutive cycles. This alarm disappears automatically when another
stable weighing has taken place.
i. This alarm does not affect the dosing behaviour if it occurs occasionally.
ii. Should the alarm not go away after a longer period please contact Ferlin.
8. No material selected.
a. No material is selected in the recipe. Click the button with (UNKNOWN MATERIAL)
and select a material.
b. Is the list of materials empty? Then go to settings -> material database and press + to
create a material. Try a. again
9. Trigger time too long.
a. The dosing signal from the injection moulding machine took a lot longer than the
previous cycle. This may be caused by a change on the injection moulding machine or
by manual operation of the injection moulding machine. You do not need to do
anything with this alarm then. Starting an stopping the Ferlin One will cause it to
learn a new time.
i. Should this occur outside the above situation, check whether the alarm
occurs more frequently. If so, the Ferlin One can be set to a fixed dosing
time. Go to Settings -> General -> production mode -> injection moulding
and select fixed time. Go back to the main screen and then to the recipe.
Enter the desired dosing time here.
10. USB full
a. The plugged-in USB is full. Plug in another USB or make room on the existing USB.
11. SD full
a. The Ferlin One's internal storage is full.
i. Please contact Ferlin
12. Backup battery voltage low
a. The Ferlin One's internal battery is low.
i. Please contact Ferlin