Problem solving
1. Screen of the controller stays black:
a. Check that the black 240v power cable is connected to the back of the control
and in the socket. Check voltage at the socket.
2. Colour of final product disappears.
a. Check that material is present in the main hopper and in the small hopper.
i. Main hopper refilled but still no colour in finished product? Wait at least 10
cycles. Then check that the small hopper has material. Open the door (3) and
take out the dosing part (6) (Disconnect the large white connector first).
Continue to ii. Or iii.
ii. Small hopper full?
1. Check for accumulation (bridging) of material. Remove this.
2. Check whether belt runs smoothly. If not: replace dosing part.
iii. Small hopper empty?
1. Then check that the 2 air hoses between the hopper and housing are
connected. Also check that the air supply is connected to the housing
or the filter pressure regulator (7). (pressure should be between 4
and 6bar)
2. Air hoses present? Re-install dosing part (6), reconnect connector
and close door (3). Perform a tarration. Go to settings -> loadcell ->
tarration and start taring.
Taring and calibration
Go to settings (gears on main screen) -> loadcell. Then open the tare or calibrate screen. Follow the
on-screen instructions to tare or calibrate.